500 kVA Oil Immersed Transformer Manufacturer
500 kVA oil immersed distribution transformer manufactured for utility, industrial and power distribution projects, with project-specific voltage configurations available according to customer requirements.
Designed for Southeast Asia, including Malaysia and the Philippines.
- 500 kVA Oil Immersed Distribution Transformer
- Customized Primary Voltage Configuration
- 50 / 60 Hz Project Configuration
- IEC / GB Compliant Production
About Yingben Transformer Factory
Yingben is a distribution transformer manufacturer based in Foshan, China, with transformer manufacturing experience since 1998.
Our 15,000 m² facility manufactures oil immersed distribution transformers, cast resin dry type transformers and compact substations for industrial, utility and power distribution projects.
Yingben supports project-specific transformer configurations, routine testing and OEM / ODM requirements for Southeast Asia, including Malaysia and the Philippines.
500 kVA Oil Immersed Distribution Transformer
Yingben manufactures 500 kVA oil immersed distribution transformers for utility, industrial and general power distribution projects.
Transformer voltage, vector group, conductor material and other technical configurations can be adjusted according to project specifications and local distribution system requirements.
For projects in Southeast Asia, including Malaysia and the Philippines, Yingben can support 50 / 60 Hz systems and project-specific voltage configurations.
Technical Data
Typical / Project ConfigurableRoutine Testing Before Delivery
Each 500 kVA oil immersed transformer is subject to routine factory testing before shipment to verify electrical performance and manufacturing quality according to the approved project specification.
Voltage Ratio Test
Verifies that the transformer voltage ratio matches the approved design.
Vector Group Verification
Confirms the transformer connection and phase displacement configuration.
No-Load Loss Test
Checks no-load electrical performance before the transformer leaves the factory.
Load Loss Test
Measures transformer load loss under specified test conditions.
Short-Circuit Impedance Test
Verifies impedance performance against the approved technical specification.
Insulation Test
Checks insulation performance as part of routine factory quality control.
Relevant factory test records can be provided according to project and customer documentation requirements.
Why Choose Yingben for 500 kVA Oil Immersed Transformers
Yingben combines transformer manufacturing experience, project customization and factory quality control to support distribution transformer projects in Southeast Asia.
Manufacturer Since 1998
Long-term experience in manufacturing distribution transformers for industrial and utility projects.
15,000 m² Manufacturing Facility
In-house production and quality control support stable transformer manufacturing and project execution.
Project Customization
Voltage, vector group, conductor material and other configurations can be adjusted according to project requirements.
Routine Testing Before Delivery
Each transformer undergoes routine factory testing before shipment, with relevant test records available when required.
IEC / GB Production Support
Transformer production and testing can be arranged according to applicable IEC, GB and approved project specifications.
Fast Production & Delivery
For standard configurations, shipment can start from the third week after technical confirmation, subject to order quantity and final project requirements.
Related Oil Immersed Transformers
Oil Immersed Transformer
View transformer details and technical configuration.
View Model → 1000 kVAOil Immersed Transformer
View transformer details and technical configuration.
View Model → 1250 kVAOil Immersed Transformer
View transformer details and technical configuration.
View Model →500 kVA Oil Immersed Transformer FAQ
Common questions about voltage configuration, testing, customization and project supply for 500 kVA oil immersed transformers.
What primary voltage options are available for the 500 kVA transformer?
Can the transformer be supplied for 11 kV, 22 kV or 33 kV systems?
Can Yingben customize the vector group and conductor material?
Is the 500 kVA transformer tested before delivery?
Can routine test records be provided?
Can Yingben supply this transformer for Southeast Asia projects?
Need a Project-Specific Transformer Configuration?
Send us your required capacity, primary voltage, secondary voltage, frequency and project specifications. Yingben will review the technical requirements and prepare a suitable transformer proposal.
Factory technical response for your project requirements.